Model |
LI-351 |
LI-501 |
LI-601 |
LI-102 |
LI-122 |
LI-152 |
LI-202 |
LI-302 |
LI-502 |
LI-702 |
LI-103 |
LI-153 |
LI-203 |
LI-303 |
Rated Power |
350W |
500W |
600W |
1KW |
1.2KW |
1.5KW |
2KW |
3KW |
5KW |
7KW |
10KW |
15KW |
20KW |
30KW |
Peak Power |
1050W |
1500W |
1800W |
3KW |
3.6KW |
3.0KW |
6KW |
9KW |
15KW |
21KW |
30KW |
45KW |
60KW |
90KW |
Nominal battery voltage |
12VDC |
12VDC/24VDC |
24VDC/48VDC |
48VDC |
96VDC |
192VDC |
240VDC |
Input |
DC input range |
10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) / 84-120VDC (96V) / 168-240VDC (192V)/210-300VDC (240V) |
AC Mains input range |
(220/230/240VAC) 140-275VAC |
170-250VAC |
AC input frequency |
50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) |
Protection |
Low battery alarm |
≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V)/ ≤210VDC (240V)alarm |
Low battery protection |
≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) /≤200VDC (240V) automatic shutdown |
High battery alarm |
≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V)/ ≥300VDC (240V) alarm |
High battery protection |
≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V)/ ≥340VDC (240V) automatic shutdown |
Over load protection |
110% more than rated capacity, automatic shutdown |
High temperature |
Built-in temperature real time sensor, ≥85ºC alarm, ≥90ºC automatic shutdown |
Short circuit protection |
Automatic shutdown |
Output |
Transfer efficiency |
≥85% |
Output voltage |
(DC battery mode) 220/230/240VAC±2% |
Output frequency |
(DC battery mode) 60/50Hz±1% |
Output wave form |
Pure sine wave |
Output voltage |
(AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer |
AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency |
(AC mains mode) automatic tracing from AC input |
Other |
Transfer time |
Bult- in AC bypass replay (≤10ms) |
Display |
LCD Display with function buttons |
Cooling system |
Intelligent cooling fan control system |
≤42ºC slow fan, ≥45ºC fast fan |
AC Charger |
AC charging Voltage |
13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V)/108.8-113.6VDC(96V)/217.6-227.2VDC(192V)/272-284VDC(240V) |
AC charging current |
Steady 15A |
AC over charge protection |
Battery >=16V (12V) >=32V (24V) >=64V (48V) >=128V (96V) >=256V (192V) >=320V (240V), stop charging after 60s alarm |
Working mode
(Optional) |
01 |
AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the battery, |
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
02 |
Energy saving |
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
03 |
DC battery priority |
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to |
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and |
automatically start charging the battery (for 24V/48V/96V/192V/240V system, multiply by 2/4/8/16/32 accordingly) |
Comnunication |
RS-232/USB/SNMP(additional option) |
Environment |
Temperature |
-20~+75ºC |
Humidity |
<95% |
Appearance |
Product size (mm) |
285*255*120mm |
310*180*300mm |
410*225*410mm |
465*270*525mm |
540*300*660mm |
670*330*720mm |
Packing size (mm) |
345*315*187mm |
380*250*350mm |
505*320*500mm |
620*375*570mm |
630*400*740mm |
760*430*800mm |
Net Weight (kg) |
7.2kg |
7.5kg |
7.5kg |
7.6kg |
8.9kg |
5.9kg |
25.5kg |
28.8kg |
45.5kg |
49.8kg |
54kg |
64kg |
74kg |
84kg |
Gross Weight (kg) |
7.7kg |
8.0kg |
8.0kg |
8.1kg |
9.4kg |
6.4kg |
27.2kg |
30.5kg |
56.5kg |
62.5kg |
68.2kg |
80.7kg |
90.7kg |
100kg |
*Product specifications are subject to change without further notice |