Model |
FT-152 |
FT-202 |
FT-302 |
FT-402 |
FT-502 |
FT-602 |
Rated Power |
1.5KW |
2KW |
3KW |
4KW |
5KW |
6KW |
Peak Power |
4.5KW |
6KW |
9KW |
12KW |
15KW |
18KW |
Nominal battery voltage |
12/24/48VDC |
24VDC/48VDC |
Input |
DC input range |
10.5-16VDC (12V) / 21-32VDC (24V) / 42-64VDC (48V) |
Standard Voltage |
220VAC |
AC Mains input range |
165-275VAC |
AC input frequency |
50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) |
Output |
Transfer efficiency |
≥85% |
Output voltage |
(DC battery mode) 220VAC±2% |
Output frequency |
(DC battery mode) 50Hz/60Hz±1% |
Output wave form |
Pure sine wave |
Output voltage |
(AC mains mode) stable 220±10% output (built-in AVR stablizer) |
AVR output stablizer |
AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V output just multiply by percentage |
Protections |
Low battery voltage alarm |
≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V) alarm |
Low battery voltage protection |
≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown |
High battery voltage alarm |
≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V) alarm |
High battery voltage protection |
≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown |
Overload protection |
loading>110%, shutdown after 60s alarm, loading>115%, shutdown after 20s alarm |
High temperature |
Built-in temperature real time sensor, ≥85ºC alarm, ≥90ºC automatic shutdown |
Short circuit protection |
Automatic shutdown |
AC Charger |
Supported battery types |
SLA/GEL/AGM/WATER/Lithium & Customize |
AC charging Voltage |
10.5-16VDC (12V) / 21-32VDC (24V) / 42-64VDC (48V) |
AC charging current |
15A |
3 Stages charging |
Boost charging, direct charging, float charging |
AC over charge protection |
>=64V (48V) >=128V (96V) >=256V (192V), stop charging after 60s alarm |
Working Mode |
Line priority mode |
The utility power (AC input/City grid) is given priority to supply power to the load, and at the same time automatically charges the battery, and stops charging when the battery is fully charged. Automatically switch battery power supply when there is no mains power |
ECO mode |
Similar as Line priority mode.When the load power accounts for less than 10% of the inverter power, the inverter will automatically shut down, and when the load power accounts for 11%~100% of the inverter power, it will automatically start |
Battery priority mode |
Prioritize the use of batteries to supply power to the load. When the battery voltage is higher than the battery recovery voltage, the battery supplies power to the load; when the battery voltage is lower than the battery low-voltage protection voltage, the inverter will automatically switch from the battery power supply to the Utility power supply, and automatically charge the battery after switching to the Utility power supply |
Generator mode |
Similar as Line priority mode.Generator output should within 165~275vac and 45~65hz. |
Unattended mode |
Inverter will always under ON or STANDBY status. when battery voltage is low , the inverter will auto shut down AC output and enter STANDBY status. Once battery been charged it back to the restore point, the inverter will restart the AC ouput. |
Other |
Transfer time |
Bult- in AC bypass replay (≤8ms) |
Display |
LCD Display with function buttons |
Cooling system |
Intelligent fan air cooling, fan speed is adjusted by real temperature. |
≤45ºC slow fan, ≥45ºC fast fan |
Comnunication |
RS485,support wifi box and external control screen for remote control and mornitoring.
(WIFI box & External Contol Screen sell seperately) |
Environment |
Temperature |
-20~+75ºC |
Humidity |
<95% |
Mesurement |
Product size (mm) |
475*300*185 |
650*300*185 |
Packing size (mm) |
600*380*270 |
780*380*280 |
Net Weight (kg) |
13.5 |
15 |
17 |
26 |
27.5 |
30 |
Gross Weight (kg) |
17 |
19 |
21 |
31 |
33 |
35 |
*Updated at Jan.2023.Product specifications are subject to change without further notice |