• 2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter
  • 2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter
  • 2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter
  • 2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter
  • 2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter
  • 2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter

2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter

Nature of Source Flow: Passive inverter
Certification: ISO9001, RoHS, CE
Output Power: >1000W
Grid Type: off-Grid Inverter
Output Type: Single
Nature of Wave String: Sine Wave Inverter
Samples:
US$ 223/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FT-202
Type
DC/AC Inverters
Surge Power
Triple
AC Input Power
110/120/220/230/240VAC
Battery Input Power
12/24VDC
Rated Power
2kw
Power Factor
3kVA
Transport Package
Carton
Specification
540*335*255MM
Trademark
ONE
Origin
Foshan, China
HS Code
8504403090
Production Capacity
5000PCS/Month

Product Description

2kw 3kva 12v 24v 48v 110v 120v 220v 230v power inverter for ups system pure sine wave off grid dc to ac inverter 
 Model FT-152 FT-202 FT-302 FT-402 FT-502 FT-602
Rated Power 1.5KW 2KW 3KW 4KW 5KW 6KW
Peak Power 4.5KW 6KW 9KW 12KW 15KW 18KW
Nominal battery voltage 12/24/48VDC 24VDC/48VDC
Input
DC input range 10.5-16VDC (12V) / 21-32VDC (24V) / 42-64VDC (48V)
Standard Voltage 220VAC
AC Mains input range 165-275VAC
AC input frequency 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition)
Output
Transfer efficiency ≥85%
Output voltage (DC battery mode) 220VAC±2%
Output frequency (DC battery mode) 50Hz/60Hz±1%
Output wave form Pure sine wave
Output voltage (AC mains mode) stable 220±10% output (built-in AVR stablizer)
AVR output stablizer AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode;
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; 
The above is for output 220V system reference, 230V output just multiply by percentage
Protections
Low battery voltage alarm ≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V) alarm
Low battery voltage protection ≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown
High battery voltage alarm ≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V) alarm
High battery voltage protection ≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown
 Overload protection loading>110%, shutdown after 60s alarm, loading>115%, shutdown after 20s alarm
High temperature Built-in temperature real time sensor, ≥85ºC alarm, ≥90ºC automatic shutdown
Short circuit protection Automatic shutdown
AC Charger
Supported battery types SLA/GEL/AGM/WATER/Lithium & Customize
AC charging Voltage 10.5-16VDC (12V) / 21-32VDC (24V) / 42-64VDC (48V)
AC charging current 15A
3 Stages charging Boost charging, direct charging, float charging
AC over charge protection  >=64V (48V) >=128V (96V) >=256V (192V), stop charging after 60s alarm
Working Mode
Line priority  mode The utility power (AC input/City grid) is given priority to supply power to the load, and at the same time automatically charges the battery, and stops charging when the battery is fully charged. Automatically switch battery power supply when there is no mains power
ECO mode Similar as Line priority mode.When the load power accounts for less than 10% of the inverter power, the inverter will automatically shut down, and when the load power accounts for 11%~100% of the inverter power, it will automatically start
Battery priority mode Prioritize the use of batteries to supply power to the load. When the battery voltage is higher than the battery recovery voltage, the battery supplies power to the load; when the battery voltage is lower than the battery low-voltage protection voltage, the inverter will automatically switch from the battery power supply to the Utility power supply, and automatically charge the battery after switching to the Utility power supply
Generator mode Similar as Line priority mode.Generator output should within 165~275vac and 45~65hz.
Unattended mode Inverter will always under ON or STANDBY status. when battery voltage is low , the inverter will auto shut down AC output and enter STANDBY status. Once battery been charged it back to the restore point, the inverter will restart the AC ouput. 
Other
Transfer time Bult- in AC bypass replay (≤8ms)
 Display LCD Display with function buttons
Cooling system Intelligent fan air cooling, fan speed is adjusted by real temperature. 
≤45ºC slow fan, ≥45ºC fast fan
Comnunication RS485,support wifi box and external control screen for remote control and mornitoring.
(WIFI box & External Contol Screen sell seperately)
Environment
Temperature -20~+75ºC
Humidity <95%
Mesurement
Product size (mm) 475*300*185 650*300*185
Packing size (mm) 600*380*270 780*380*280
Net Weight (kg) 13.5 15 17 26 27.5 30
Gross Weight (kg) 17 19 21 31 33 35
*Updated at Jan.2023.Product specifications are subject to change without further notice
2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter2kw 3kVA 12V 24V 48V 110V 120V 220V 230V Power Inverter for UPS System Pure Sine Wave off Grid DC to AC Inverter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now