Customization: | Available |
---|---|
Warranty: | 12 Months |
Nature of Source Flow: | Passive inverter |
Still deciding? Get samples of US$ 72.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | HI-351 | HI-501 | HI-601 | HI-801 | HI-102 | HI-122 |
Rated power | 350W | 500W | 600W | 800W | 1000W | 1200W |
Surge power | 1050W | 1500W | 1800W | 2400W | 3000W | 3600W |
AC Input & Output | ||||||
Voltage | 220VAC | |||||
Selectable Voltage Range | 165-275VAC (220VAC) | |||||
Frequency Range | 50Hz/60Hz automatic recognition | |||||
AC Voltage Regulation | (DC Batt.mode)220vac±3% | |||||
(BATT. Mode) | ||||||
Transfer Time | ≤8ms | |||||
Wave Form | Pure Sine Wave | |||||
Transformer type | Toroidal | |||||
Transfer efficiency | ≥85% | |||||
Battery | ||||||
Battery Voltage | 12V | 12V/24V | ||||
Type | Gel/SLA/AGM/Water battery | |||||
DC Charge Voltage | 13.8VDC(12V)/27.6VDC(24V) | |||||
Overcharge Protection | Battery voltage >=16VDC (12V) >=32VDC (24V), stop charging after 60s alarm | |||||
AC Charger | ||||||
Maximum Ac Charge Current | 15A | |||||
Working mode | ||||||
01 mode | AC mains priority | |||||
02 mode | ECO mode | |||||
03 mode | DC battery priority | |||||
Physical | ||||||
Dimension, | 360*328*212 | |||||
D*W*H(MM) | ||||||
G.W.(KGS) | 10 | |||||
Environment | ||||||
Humidity | 0~95%(NO CONDESNSATION) | |||||
Operating Temperature | 0~60ºC | |||||
Storage Temperature | 0~60ºC | |||||
*Product Specifications Are Subject To Change Without Further Notice |