Model | FI-102 | FI-152 | FI-202 | FI-302 | FI-402 | FI-502 | FI-602 | FI-702 |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 7KW |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | 21KW |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC |
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) |
AC Mains input range | 140-275VAC (220/230/240VAC)±4% |
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) |
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm |
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown |
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm |
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown |
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm |
High temperature | Built-in temperature real time sensor, ≥85ºC alarm, ≥90ºC automatic shutdown |
Short circuit protection | Automatic shutdown |
Output | Transfer efficiency | ≥90% |
Output voltage | (DC battery mode) 220/230/240VAC±2% |
Output frequency | (DC battery mode) 60/50Hz±1% |
Output wave form | Pure sine wave |
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency | (AC mains mode) automatic tracing from AC input |
Other | Transfer time | Bult- in AC bypass replay (≤5ms) |
Display | LCD Display with function buttons |
Cooling system | Intelligent cooling fan control system |
≤42ºC slow fan, ≥45ºC fast fan |
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) |
Deep sulphation cycle 15.5 for 4 hrs |
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) |
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages charging current adjustable |
3 Stages charging | Boost charging, direct charging, float charging |
AC over charge protection | Battery voltage >=16VDC (12V) >=32VDC (24V) >=64VDC (48V), stop charging after 60s alarm |
Working mode (Optional) | 01 | AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the battery, only |
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
02 | Energy saving |
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
03 | DC battery priority |
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts |
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC |
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) |
Communication | RS-232/USB/SNMP(additional option) |
Environment | Temperature | -20~+75ºC |
Humidity | <95% |
Appearance | Product size (mm) | 460*245*200mm | 630*280*200mm |
Packing size (mm) | 530*335*255mm | 740*355*275mm |
Net Weight (kg) | 15kg | 18kg | 21kg | 24.5kg | 30kg | 32kg | 34kg | 38kg |
Gross Weight (kg) | 17.3kg | 20.3kg | 23.3kg | 26.8kg | 33.4kg | 35.4kg | 37.4kg | 41kg |
*Product specifications are subject to change without further notice |